7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some staining of pool plaster especially at bench area and on pool floor. Plaster shall be maintained to reflect >50% light. Stain does not appear to be this dark at time of inspection. Continue to monitor. May require treatment in future if worsens. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Severe offset on decking at back of deck near retaining wall. Offset greater than 1/2". Requires repair prior to January 31st. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Flow meter not installed per mfg. instructions. Piping available does not allow for at least 5x pipe diameter on inlet side. Pipe is 4" and requires at least 20" of pipe. Flow meter reading not taken since flow meter is not installed per mfg. specifications. Re-plumb to ensure flow meter is installed per mfg. instructions.
Filter, valves for skimmer lines and flow meter not easily accessible. Pump room shall require at least 3 ft. clear walking space around equipment.
Chlorine and acid tanks stored in pump room. Shall be stored in chemical storage room with corrosion resistant ventilation.
Given until January 31st to complete the above items. |