Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameKENDRY, THE
Address8408 IBM DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/5/2023
Final Score @ Grade
10
General Comments6 - Equalizer lines not plugged in skimmer. Given 30 day to plug per State requirements. Water shall be evacuated from the line and permanently plugged. Drain cover not flush to pool floor. Looks damaged; however, still secure. Repair drain cover to be installed per mfg. instructions. Given 30 days to repair. Rick Luna present during the inspection. Either salt or chlorine approved for primary chlorination. Salt cell is sized for 40,000 gallons. Pool size is 31,000 gallons.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some staining of pool plaster especially at bench area and on pool floor. Plaster shall be maintained to reflect >50% light. Stain does not appear to be this dark at time of inspection. Continue to monitor. May require treatment in future if worsens.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Severe offset on decking at back of deck near retaining wall. Offset greater than 1/2". Requires repair prior to January 31st.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Flow meter not installed per mfg. instructions. Piping available does not allow for at least 5x pipe diameter on inlet side. Pipe is 4" and requires at least 20" of pipe. Flow meter reading not taken since flow meter is not installed per mfg. specifications. Re-plumb to ensure flow meter is installed per mfg. instructions. Filter, valves for skimmer lines and flow meter not easily accessible. Pump room shall require at least 3 ft. clear walking space around equipment. Chlorine and acid tanks stored in pump room. Shall be stored in chemical storage room with corrosion resistant ventilation. Given until January 31st to complete the above items.