NameAVENTINE APARTMENTS
Address13035 ARDMORE FOREST RD
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/20/2025
Final Score @ Grade
16
General CommentsInspection conducted with CPO Jesse Godwin. Overspray from water features puddles on deck. Maintain deck sloped to drain and free of standing water. Outer rope on ring buoy fraying. Recommend replacing with new US Coast Guard approved ring buoy. Intent to suspend issued 8) 16) 24) Intent to suspend items must be corrected before current permit expires on 5/31 or permit will be suspended. Contact Will Harrison (704) 507-6824 to schedule re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer basket bottom broken. .2518(k) Replace missing or damaged skimmer basket. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder loose. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One gate not self-closing. One gate not self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item. > 2 inch gap under fence in places, especially around landscape drains. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum off in pump room. One vacuum cap damaged. .2518(f) Provide a self-closing vacuum cap for pools built after May 1, 2010. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Bag of soda ash on floor of the chemical storage room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.