Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameALEXAN RESEARCH PARK
Address9821 RESEARCH DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/28/2026
Final Score @ Grade
34
General CommentsNote: Heater not on at time of inspection. Intent to Suspend issued for the following: .2535 - maintain daily log for main drain checks - provide section in log book. .2523 - replace 4 ft. wall depth marker where missing. .2524 - provide documentation (pictures) of sufficient lighting on deck and inside pool for night swimming approval or change signage to indicate 10:00 am to dusk. .2537 - repair opening at coping and deck where >1/2". Luis Cruz-Pena present during the inspection. Flow range required for filtration pump at 77 gpm to 138 gpm.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Some days missing record keeping over past several months. Ensure daily record keeping for chlorine, pH and main drain checks. No section in log book for main drain checks. Provide section for daily record keeping for main drain checks. Intent to Suspend issued. DPD-1 and 2 expired. Replace expired reagents.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Waterline tile missing in multiple locations around pool. Replace tile. Keep pool walls in good repair. Pool operator stated that pool will be replastered in offseason. If drain covers are replaced during replaster, new PDSC forms are required.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Missing 4 ft. wall depth marker. Provide wall depth marker at 4 ft. Intent to Suspend issued.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No New rope for ring buoy measured at 57 ft. Required at 31 ft. Cut during the inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No >1/2" between coping and deck at corner angle near pergola area. Repair opening to ensure no openings >1/2". Intent to Suspend issued.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Pool hours indicate 10:00 am to 8:00 pm. Pool is not approved for night swimming. Pool on photocell. Operator demonstrated all lights operable on pool deck and inside of pool during the inspection by covering the photocell. Provide documentation of sufficient lighting on pool deck and inside pool for final approval of night swimming or signage must be changed to indicate 10:00 am to dusk. Intent to Suspend issued. Drawing completed during site inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Small leak at pool filtration pump and at drain line for filter. Did not warrant repair at time of inspection. If worsens, repair.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leaks at equipment. Keep dry. Forced ventilation not on in pump room and chemical storage room during inspection. Turned on during the inspection. Dry chemicals stored on pump room floor and chemicals stored in pump room. Store all dry chemicals up off the floor and in approved chemical storage room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Far sink in women's restroom closest to stalls not operable. Keep all fixtures operable.