Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHICKORY WOODS APARTMENTS
Address5625 KEYWAY BOULEVARD
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/5/2025
Final Score @ Grade
20
General CommentsINSPECTION WITH HUNTER DELAO PRESENT. PERMIT RESTRICTIONS: FLOW METER MUST REMAIN OPERABLE. FLOW SHALL BE AS CLOSE TO 98 GPM DUE TO FILTER FLOW RESTRICTION. TURNOVER NOT MET AT 109 GPM DUE TO SYSTEM RESTRICTIONS. MAIN DRAIN COVERS AND EQUALIZER LINE COVERS EXPIRE 3/1/2028 POOL CLOSED BY ORDER OF THE HEALTH DEPARTMENT. POOL CANNOT REOPEN WITHOUT VERIFICATION OF CORRECTION BY THE HEALTH DEPARTMENT. CONTACT C. ELMORE AT 704-507-6814 WHEN THE CORRECTIONS ARE MADE.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be 8.0. Suspension issued.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing or damaged skimmer basket. Observed the skimmer baskets to have damage. Replace the skimmer baskets. No Permit Action taken. Observed skimmer damaged such that water can get under the skimmer and cause damage. Fix the skimmer.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed sections of fencing at the units with patios that are next to the pool deck to have barriers that are not to current specifications. Observed other areas of the fence not to current specifications. The barrier is pre 2010. 100 ft. Out of 312 ft. Was recently replaced with new fence. No Permit Action taken.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed multiple deck furniture items to be too close to the water edge. Items were moved to proper locations. -CDI.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at the back flow line.