Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHICKORY WOODS APARTMENTS
Address5625 KEYWAY BOULEVARD
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/5/2024
Final Score @ Grade
24
General CommentsObserved deck coating peeling up at the stairs. This should be addressed before it gets worse. Observed the vacuum cap cover to be worn. It is recommended to replace the cover before it gets more worn and easier to open. POOL IS CLOSED BY ORDER OF THE HEALTH DEPARTMENT. POOL CANNOT REOPEN FOR SWIMMING WITHOUT ON-SITE VERIFICATION OF THE CORRECTION OF THE CLOSURE ITEMS. CONTACT C. ELMORE AT 704-507-6814 WHEN CORRECTIONS ARE MADE.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed 0.6 PPM in the pool, this is not enough chlorine to operate safely. Chlorine must be corrected by proper chlorination through the chlorine system. It cannot be corrected simply by putting chlorine into the pool directly.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed records not being properly kept. Keep proper records with accurate readings. Observed no records kept after 11/12/2024. Proper records must be kept for every day the pool is open.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed sections of fencing at the units with patios that are next to the pool deck to have barriers that are not to current specifications. The barrier is pre 2010. 100 ft. Out of 312 ft. Was recently replaced with new fence. No Permit Action taken.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed multiple deck furniture items to be too close to the water edge. Items were moved to proper locations. -CDI.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. This pool has a flow requirement of 98 GPM. The flow meter must be functional.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at the back flow line.