Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTAYLOR FARMS LUXURY APARTMENT HOMES
Address2311 ODELL SCHOOL RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/10/2025
Final Score @ Grade
28
General CommentsInspection conducted with inspector Rusi Woo and CPO Theo Hancock. Permit condition that flow is required at 143-220 GPM. Verified at 155 GPM. Permit condition that feature pump be set at no more than 3110 RPM. Observed at 1550 GPM. New pool filtration pump installed. Pentair Intellifo XF VSF 022056. Like for like change. Does not need in-field plan review, does need passing electrical inspection. Checked with office, failed electrical inspection for GFCI on 6/30/2025. Immediate suspension issued 3) Contact Will Harrison

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 8.0. .2535(1) Maintain pH at 7.2 to 7.8.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No place on log sheet for temperature checks. Spotty total alkalinity and cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Some skimmer baskets full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing one endcap. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw ropes 44 feet long for ring buoys. .2530(a) Provide USCG approved ring buoy with attached 48 foot throw rope at least 1/4 inches in diameter. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Heater to pool installed outside the pump room. Panel is unlocked. .2525(b) Heaters shall be equipped with thermostatic controls capable of assuring that the maximum operating temperature of heated public swimming pools other than spas does not exceed 90 degrees Fahrenheit. Such controls shall be accessible only to the operator. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some items stored by pumps and equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Bag of soda ash on the floor in the chemical storage room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.