Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWILLOWS AT THE UNIVERSITY
Address625 ELTHAM RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/13/2023
Final Score @ Grade
36
General CommentsImmediate Suspension issued for the following: .2530 - provide USCG approved ring buoy with 50 ft. rope .2530 - secure body hook to pool .2530 - phone not operable. Phone shall connect to 911 with correct address and phone number posted. Phone shall answer automatically when number is dialed. CPO not present during inspection. Pool closed signs posted and gates locked during inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir stuck on sun shelf. Could not move even after hitting with end of roller. Keep weirs functional. One skimmer with debris under basket covering entire bottom of skimmer. Keep free of debris.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 1/2 ft. on deck of sun shelf loose and not slip-resistant. Replace with slip-resistant tile. ITS item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Grab rope on ring buoy degraded and broken. Rope also degraded, brittle and appears will break. Immediate Suspension issued. Replace ring buoy with USCG approved buoy and 50 ft rope. Immediate Suspension issued. Body hook secured to pole with zip ties. Secure with screws or permanent solution that can't be removed. Immediate Suspension issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Both gates not self-closing, self-latching. Repair to self-close, self-latch. >1/2" between post and gate at gate to left of clubhouse from exit on to pool deck. Maintain 1/2" or less between post and gate. Metal removed from gate on right side from exit to pool deck where meshing is >1/2". See other gate for example. Eliminate openings >1/2" within 18" of push bar. Door from fitness locked. Door shall self-close, self-latch. EHS shall have access. ITS items for all items above.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool furniture less than 5 ft. to pool edge. Maintain 6 ft. clearance around the pool in all locations.
22 6 Premises: emergency telephone provided No No No Phone not operable. When button pushed, does not connect to 911. Phone shall connect to 911. Correct address and phone number shall be posted. Phone shall answer automatically when number dialed. Immediate Suspension issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automated feeder for chlorine and pH. Feeder reading 8.1 while pH at 7.6. Calibrate feeder. Could not verify that feeder detects flow. Operator not present during inspection. EHS shall be able to verify that feeder detects flow and turns off with no flow.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light burnt out in pump room. Repair/replace light where needed.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap, paper towels, or toilet paper in outdoor restrooms. Provide soap, paper towels and toilet paper.