10
|
1
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
5-205.11 (B) A handwashing sink may not be used for purposes other than handwashing Pf.Observed debris in hand sink. Also observed cup in hand sink. CDI.. Cup was removed
5-205.11 (A) A handwashing sink shall be maintained so that it is accessible at all times for employee use Pf. Observed boxes blocking hand sink.. EHS had PIC move boxes |
|
37
|
1
|
Food properly labeled: original container |
No |
Yes
|
No |
3-302.12 Label all working containers of food (oils, spices, salts, flour, sugar) except food that is easy to identify such as dry pasta. Observed squeeze bottles without lables.REPEAT |
|
48
|
0
|
Warewashing facilities: installed, maintained & used; test strips |
Yes |
No
|
No |
4-501.19 During manual warewashing, maintain the wash solution at a minimum of 110F or as otherwise allowed by the detergent manufacturer label. -Pf Observed employee actively washing dishes, water temp 106. CDI.. Made new dish water. |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-403.11 (A)Areas designated for employees to eat and drink, shall be located so that food, equipment, linens, single service/use items are protected from contamination.Observed a bottle of water over prep unit. |