38
|
0
|
Insects & rodents not present; no unauthorized animals |
No |
No
|
No |
6-202.15 - Outer Openings, Protected: Protect outer openings of establishment from insect or rodent entry.
In order to help air flow for the reach in cooler, a fan was used at an opening in the rear where no screen is available. REHS recommends adding a screen to this area if the opening will continue to be used to increase air flow. |
|
41
|
0.50
|
Wiping cloths: properly used & stored |
Yes |
No
|
No |
3-304.14 - Wiping Cloths, Use Limitation: Hold in-use wiping cloths in sanitizer between uses.
(REPEAT) Bleach sanitizer read at 0ppm in container. CDI by PIC making a new bucket. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-202.15 - Can Openers: Cutting or piercing parts of can openers shall be readily removable for cleaning and for replacement.
Available table mounted can opener needs a hand tool in order to remove blade. This must be replaced with a can opener that can be easily removed. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-201.17 - Walls and Ceilings, Attachments: Attachments to walls and ceilings such as light fixtures, mechanical room ventilation system components, vent covers, wall mounted fans, decorative items, and other attachments shall be easily cleanable.
The ceiling vent grate over the dry storage area has rusting paint. |