10
|
0
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf.
Observed hand sink with no paper towel.
CDI - Paper towel was placed at the hand sink. |
|
16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
Yes |
No
|
No |
4-501.114 Maintain sanitizer at correct concentrations when being used to sanitize. -P
For more information please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg and How to Test Sanitizer https://youtu.be/y0SjmnabFaY
Observed QUAT sanitizer at 0 PPM inside the 3 compartment sink.
CDI- Employees will manually mix sink sanitizer until line is repaired. |
|
40
|
0.50
|
Personal cleanliness |
No |
Yes
|
No |
2-402.11 Use head coverings, beard guards and clothing to restrain body hair from contacting exposed food, equipment, and utensils.
Observed food employees with no head covering. |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
No |
4-302.14 Provide a test kit that accurately measures sanitizer concentrations. -Pf.
Establishment could not provide correct test strips for chlorine sanitizer.
EHS 10 Verification visit required. |