Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLINK APARTMENTS MINT STREET
Address1200 S MINT ST
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/26/2026
Final Score @ Grade
10
General CommentsPOOL WAS APPROVED FOR NIGHT SWIMMING. C. ELMORE WILL PERFORM NIGHT SWIMMING EVALUATION BEFORE THE END OF THIS YEAR. ENSURE PROPER LIGHTING FOR NIGHT TIME USE. PERMIT RESTRICTIONS: Requires 5% flow meter for 2026 for feature. Permit Restrictions: 1) Filtration flow meter shall remain operable. Flow required at 66 gpm to 80 gpm to meet turnover and flow restrition of the number of returns. 3) Sump pump or other means required to drain the pool. 4) Feature pump required set at 1500 gpm or less. Flow meter must remain operable. Flow required less than 145 gpm due to drain cover flow restriction. Suction Hazard. 5) Feature pump system cannot be turned on until the new 5% flow meter installation and compliance is verified by the Health Department. Note: Pool is approved with salt as primary chlorination. MAIN DRAIN COVERS EXPIRE 3/14/2028 POOL HAS PASSED INSPECTION AND BEEN ISSUED PERMIT DECAL. POST PERMIT DECAL AND PAPER POOL PERMIT DOCUMENT AT THE POOL. THE PAPER PERMIT SHOULD BE AVAILABLE WITHIN 1-3 BUSINESS DAYS ON THE HEALTH DEPARTMENT POOL WEBSITE.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed the emergency phone number posted to be 980-236-8405 which was determined to be incorrect. The correct number (980-236-8705) was posted. -CDI
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No The feature pump system is operating on a reduced flow requirement and must have a 5% accurate flow meter installed. The system is currently turned off. The system cannot be turned back on until after a new flow meter is installed and the flow is verified to be in compliance with the restriction. (1,500 RPM on the motor with a flow less than 145 GPM). Contact C. Elmore when this is corrected. (704-507-6814). C. Elmore will follow-up to ensure correction.