Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFAIRWAYS AT BIRKDALE
Address16501 STONEMASON DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/15/2024
Final Score @ Grade
20
General CommentsInspection conducted with CPO Ed Maranelli. One equalizer line plugged, dummy cover in place. Will need to remove dummy cover and plug per state guidelines when cover expires 2-8-2025. Equalizer line covers expire 2-8-2025. Replace with new ANSI/APSP/ICC-16 approved drain covers and provide updated Pool Drain Suction Compliance form to our office for approval prior to drain cover expiration. Ensure all windows that open on to the pool deck are not capable of opening > 4” Error in processing permit. Permit issued Paper permit will be on our website in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No No flow through 3 of the far skimmers. Recommend cleaning out the lines. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. One weir missing. .2518(k) Replace missing weirs. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders extend > 6” into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
22 6 Premises: emergency telephone provided No No No Emergency phone calls back to main line for the office. Needs to be a dedicated line that calls back to the emergency phone. .2530(f) Emergency phone shall remain operable. - Will follow up with the facility to ensure it is corrected.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some labeling worn off or missing. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.