8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
No flow through 3 of the far skimmers. Recommend cleaning out the lines. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50.
One weir missing. .2518(k) Replace missing weirs. - Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladders extend > 6” into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone calls back to main line for the office. Needs to be a dedicated line that calls back to the emergency phone. .2530(f) Emergency phone shall remain operable. - Will follow up with the facility to ensure it is corrected. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some labeling worn off or missing. .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap. |