Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFAIRWAYS AT BIRKDALE
Address16501 STONEMASON DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/21/2023
Final Score @ Grade
14
General CommentsInspection conducted with CPO Ed Maranelli. One equalizer line plugged. Dummy cover in place. Will need to remove dummy cover and plug per state guidelines when cover expires 2-8-2025. Intent to suspend issued. 9) 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No No flow in one of the skimmers. Recommend cleaning out the line. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Some depth marker stickers missing. Original depth markers are not the international no diving symbol. .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Gate latch < 54” high on two of the gates due to the mulch. .2528(a) Gate latches shall be 54" in height. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.