8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
No flow in one of the skimmers. Recommend cleaning out the line. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Some depth marker stickers missing. Original depth markers are not the international no diving symbol. .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. - Intent to suspend item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Gate latch < 54” high on two of the gates due to the mulch. .2528(a) Gate latches shall be 54" in height. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. |