Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameVERANDAS AT LAKE NORMAN
Address18510 THE COMMONS BLVD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/19/2024
Final Score @ Grade
22
General CommentsInspection conducted with CPO Ed Marinelli. Issues from previous inspection corrected. Conducted full inspection. Main drains expire 12-16-2024. Replace with ANSI/APSP/ICC-16 approved drain covers and provide updated Pool Drain Suction Compliance form to MeckPools@MeckNC.gov for approval prior to main drain expiration. Equalizer line covers expire 2-22-2026. One equalizer line plugged under the skimmer with dummy equalizer line cover. Will either need to abandon per state guidelines or remove plug prior to make equalizer line operational prior to equalizer line cover expiration. *Note* 2” flow meter not capable of accurately measuring the pool flow. Piping is reduced to 2” line to go to the two filters, but does not expand back until after the flow meter.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 8.4. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.8.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No PDSC form does not match what we have on file. One skimmer equalizer plugged in the skimmer. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Corrected. Updated PDSC form submitted and approved.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing endcaps. .2521 Install ladders per manufacturer instructions. Ladder extends > 6" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Handrail missing escutcheon plate. .2521 Install handrails per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door to clubhouse catches on rug. Does not self-close. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Liquid chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash from one of the filters extends into backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.