Premises Information

Return to Inspections
NameVERANDAS AT LAKE NORMAN
Address18510 THE COMMONS BLVD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/6/2023
Final Score @ Grade
26
General Comments22 - Emergency phone not visible from all areas of the pool deck. Provide additional signage visible on pool deck within 30 days for location of emergency phone. Intent to Suspend issued for the following: .2535 - record keeping - maintain chlorine, pH and main drain checks daily; lower CYA to 100 ppm or less .2530 - provide signage - "Warning - No Lifeguard on Duty" in 4" lettering; "Adults should not swim alone" and "Children should not use the swimming pool without adult supervision" in 1" lettering; no pets and no glass, no size requirement for lettering. .2528 - repair openings around push bars so no greater than 1/2" within 18" of push bar on all gates. Edward Marinelli present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Daily record keeping missing from logs on some days in November. Ensure daily record keeping for chlorine, pH and main drain checks. Cyanuric acid >100 ppm. Maintain at 100 ppm or less. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder missing end caps. Provide end caps to eliminate potential damage to pool wall.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No All gates with meshing within 18" of push bar >1/2". Maintain no openings greater than 1/2" within 18" of push bars on all gates. Intent to Suspend issued.
18 4 Premises: lifeguards present or warning signs posted No No No Provide signage - "Warning - No Lifeguard on Duty" in 4" lettering; "Adults should not swim alone" and "Children should not use the swimming pool without adult supervision" in 1" lettering; no pets and no glass, no size requirement for lettering. Missing from pool deck or not correct wording. Intent to Suspend issued.
19 4 Premises: signs prohibit glass containers or pets in pool area No No No No glass/no pets signage not present. Provide visible upon entry to the pool. Intent to Suspend issued.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Leak at multi-port. Ensure no leaks in pump room.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Liquid chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. Provide air gap. Original construction.