24
General CommentsConducted inspection with CPO Christian. Intent to suspend issued for decking offsets, chairs too close to pool, and main gate not self closing self latching. Items must be corrected within 30 days or a permit suspension may be issued. Call EHS Devon Moeller when items are corrected and ready for re inspection. 7049981122

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. 1 out of 3 weirs missing. Replace missing weir for skimmer by fence. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Main gate not self closing self latching. Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed several chairs closer than 6ft to pool edge. Intent to suspend item. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Several areas around pool and around entrances have offsets at or greater than 1/2” Previous inspections have noted the tiles shifting and the issue getting worse. Fill in gaps and repair offsets. Intent to suspend item.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Facility address missing from emergency phone sign. Operator corrected. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting. Chemicals stored in pump room. Pool built in 2000.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. No air gap.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(h) Shower(s) shall be provided. Shower not operational.