Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMONTFORD AT MADISON PARK
Address1420 ESTATES AVE
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/22/2024
Final Score @ Grade
26
General CommentsMaintenance supervisor not available during inspection due to being at a different property. Property manager Devon gave EHS access to pool and pump room. Window limiters have been installed on pool facing resident windows. EHS verified by pictures. Pool remaining on E status due to improper length of ring buoy rope and inoperable emergency telephone. Contractor installing mesh on gate and new magna latch during inspection. Call EHS Devon Moeller when ready for re inspection. 7049981122 Permit Restriction: Flow meter must remain operable. Flow shall not exceed 119 gpm due to drain cover flow restriction.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. EHS measured rope at 40’. Cut rope to 27’. Immediate suspension item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate with magna-latch less than 54" from ground. Gate with horizontals <45" apart. Raise height of magna-latch at 54" from ground. Gate horizontals shall be >45" apart. Eliminate top horizontal by blocking off. Ie. Plexiglass or mesh. Contractor installing mesh and new magna latch during inspection. Full barrier with horizontals less than 45" apart. Maintain at 45" apart. Pool built pre-2010.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed several chairs closer than 6ft to pool edge. Intent to suspend item.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Emergency phone experiencing heavy feedback on both ends. EHS was able to barely hear and understand emergency operator. EHS unable to call back emergency phone. Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting. Chemicals stored in pump room. Pool built in 2000.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. No air gap.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(h) Shower(s) shall be provided. Shower not operational.