NameCOURTYARD BY MARRIOTT-CITY CENTER
Address237 S TRYON ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/10/2026
Final Score @ Grade
16
General CommentsOSV to pool with manager, Tanique Odom, for operating permit inspection. New pump and drain covers installed. Verified the following for IFPR during the site visit. 1) Blue white flow meter reading 55 gpm. Required at 32 gpm to 63 gpm. 2) Jandy VS FloPro VSFHP130DV, 1.3 THP pump. 3) All piping - 2" through slab. 4) New Aquastar R9FMxxx drain covers - ok with screw installation, per Aquastar. Text with Steve Barnes to confirm. Screw pattern approved by Aquastar for installation. 5) Pentair TR100C filter. 6) (4) wall returns 7) (2) Hayward skimmers Permit issued for no night swimming. State permit will be posted online by end of business on 7/10. Sticker issued while onsite.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Overlay depth markers on deck not slip-resistant. Removed during the inspection. All deck depth markers shall be slip-resistant. Wall depth marker at 2 ft. 6 in. with some lettering worn off. Corrected during the inspection. Filled in with permanent marker.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Double doors into pool deck not latching. Magnet latch. Doors leading into the hall before the restrooms are self-closing, self-latching. Door on right side must remain locked. Given one week to repair the doors directly on to the pool deck. Doors shall self-close, self-latch.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Storage in chemical storage room so chemicals not easily accessible. Maintain chemical storage so that the chemicals can be easily attainable. Fan in pump room does not appear to be operable. Ventilation shall be provided in pump room and chemical storage room. Pipe from pump to filter runs across floor. Provide 3 ft. clearance around all equipment so that valves/equipment is accessible without trip hazard.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash plumbed directly into pipe. Provide air gap at backwash line to pit.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >114 F. Maintain at 110 F or below.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Hose bib in pump room without backflow prevention. Provide backflow prevention device on hose bib.