Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOURTYARD BY MARRIOTT-CITY CENTER
Address237 S TRYON ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/30/2025
Final Score @ Grade
36
General CommentsOSV to pool with Chris Drew for inspection.SCOPE - Gas fire pit added to the pool patio; re-surfacing deck like for like; converting guest laundry into a small bar for pool patio --disposables only. Pool deck renovated to include addition of fire pit and deck being resurfaces with slip resistant coating. Guest laundry room converted to "bar" with window that opens on to pool deck. Height of wall not at 48". Kitchen area part of pool deck. Restrooms renovated. Provide flooring specs for slip resistant flooring for hold release and final approval. Permit Restriction: Door to kitchen shall remain self-closing, self-latching. No glass in kitchen. 911 had different phone number listed when called. Phone number posted dials back to emergency phone as does the number listed with 911. Appears phone is set up on a "trunk" line. A designated line must be provided. Given 30 days to correct. Intent to Suspend issued for the following: .2523/.2537 - repair/replace No Diving markers where damaged with international no diving or no diving in 4" lettering .2537 - replace missing return fitting .2523/.2537 - provide depth marker at shallow end near steps where missing. .2528 - repair both sets of doors to self-close, self-latch .2535 - provide new test kit; record cyanuric acid and total alkalinity A permit application and fee have not been received. Once payment has been made, the year permit expires on June 1. ITS items must be corrected and a return visit made or permit will not be renewed. The pool shall close on June 1 until items are corrected and verified by this department. Pool heater off at time of inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Pool pH at 8.4. Corrected to 7.4 during the inspection.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No CYA and Total alkalinity not recorded weekly. Record weekly. Intent to Suspend issued. Chemical reagents all expired. Replace reagents. Intent to Suspend issued.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Two damaged no diving markers on deck. Replace with slip resistant international no diving markers or No Diving in 4" lettering. Intent to Suspend issued. >25 ft. between depth markers on the deck at handicap side of pool. Depth marker on pool wall and not on deck. Provide depth markers on deck above 2 ft. 6 in. Intent to suspend issued.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One return on wall missing fitting. Replace fitting. Intent to Suspend issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Left side front door and back door to pool deck not staying latched or latching when closed. Repair all doors to self-close, self-latch. Intent to Suspend issued. Could not verify if battery back-up present on the front double doors. Magnet lock. Ensure battery back-up provided so that door stay latched with loss of power. Windows could not be verified with be limited at 4". All windows that open on to the pool deck shall be limited at 4" or less.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Pool seeking night swimming approval. Lights in pool not operable. Repair lights. Provide documentation showing sufficient lighting present for night swimming approval. Pool will not be permitted for night swimming approval until lights are repaired.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operable. No flow restrictions on system. Repair flow meter.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pipe across floor in pump room in walkway to equipment/valves. Ensure 3 ft. clearance around all equipment.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Hose bib in pump room without backflow prevention device. Provide backflow prevention device on hose bib. No air gap at backwash line to pit. Provide air gap. Original construction.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Restrooms renovated with new flooring, part of scope of work for renovation. Provide slip resistant flooring specs for new tile in restrooms.