| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 8.4. Corrected to 7.4 during the inspection. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
CYA and Total alkalinity not recorded weekly. Record weekly. Intent to Suspend issued.
Chemical reagents all expired. Replace reagents. Intent to Suspend issued. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Two damaged no diving markers on deck. Replace with slip resistant international no diving markers or No Diving in 4" lettering. Intent to Suspend issued.
>25 ft. between depth markers on the deck at handicap side of pool. Depth marker on pool wall and not on deck. Provide depth markers on deck above 2 ft. 6 in. Intent to suspend issued. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One return on wall missing fitting. Replace fitting. Intent to Suspend issued. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Left side front door and back door to pool deck not staying latched or latching when closed. Repair all doors to self-close, self-latch. Intent to Suspend issued.
Could not verify if battery back-up present on the front double doors. Magnet lock. Ensure battery back-up provided so that door stay latched with loss of power.
Windows could not be verified with be limited at 4". All windows that open on to the pool deck shall be limited at 4" or less. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Pool seeking night swimming approval. Lights in pool not operable. Repair lights. Provide documentation showing sufficient lighting present for night swimming approval. Pool will not be permitted for night swimming approval until lights are repaired. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operable. No flow restrictions on system. Repair flow meter. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pipe across floor in pump room in walkway to equipment/valves. Ensure 3 ft. clearance around all equipment. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Hose bib in pump room without backflow prevention device. Provide backflow prevention device on hose bib.
No air gap at backwash line to pit. Provide air gap. Original construction. |
|
32
|
2
|
Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean |
No |
No
|
No |
Restrooms renovated with new flooring, part of scope of work for renovation. Provide slip resistant flooring specs for new tile in restrooms. |