| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Pool chlorine at 0.2 ppm. Logs showed 2.0 ppm. Maintain at least 1.0 ppm through chlorinator. Chlorinator turned up during the inspection but no movement of chlorine. May indicate blockage of line of tabs added and no increase in chlorine. Immediate Suspension issued. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH less than 6.8. Logs indicated 7.0. Maintain at 7.2 to 7.8. If pool pH is recorded as less than required value, pool should be closed to the public until corrected. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No logs for cyanuric acid. Operator was recording calcium. Recorded CYA while onsite.
DPD-1 and 2 expired. Replace reagents. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
6 of 6 in and t of 3 ft with faded lettering. Provide clearly visible depth marker on pool wall - should read 3 1/2 ft. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder loose. Tighten and keep in good repair. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some damage to deck where pool cover used to be attached to pool deck. Patch hole.
Some algae build-up on deck outside of required deck space. Eliminate algae growth. Does not appear slick. Address as needed. Will require correction if worsens. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operational. Repair flow meter.
Multiport leaking when chlorinator valve changed. Substantial leak at chlorinator when valve changed. Repair leaks. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room floor wet due to leaks. Keep dry. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Label skimmer line and main drain line in pump room. Not labeled. Corrected while onsite. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No air gap at backwash line to pit. Provide air gap. |