Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameGRACE AT TRYON, THE
Address8110 GRACE FARMS DR
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/5/2023
Final Score @ Grade
20
General CommentsPermit issued for no night swimming. Elisha Griffin present during the inspection. PERMIT RESTRICTIONS: 1) SALT IS NOT APPROVED AS PRIMARY CHLORINATION. 2) FLOW METER MUST REMAIN OPERABLE. FLOW RANGE AT 74 GPM TO 140 GPM TO MEET TURNOVER AND NOT EXCEED RETURN NUMBER RESTRICTION. 3) DOUBLE DOORS FROM CLUBHOUSE MUST REMAIN WITH ONE DOOR PERMANENTLY AFFIXED AND NO SENSOR INSTALLED. 4) MAINTENANCE GATE - ONE GATE SHALL REMAIN PERMANENTLY AFFIXED CLOSED UNLESS IN USE. 5) FRESH AIR INTAKE UNDER PUMP/CHEMICAL STORAGE ROOM DOORS. Provide spare pump basket for pump within 1 week. Adjust timer on mag-lock within 1 week so that door latches within 15 seconds. Recommend switching screws in body hook to face opposite direction so not to present a hazard.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Logs without section for main drain checks. Added during inspection. Ensure daily record keeping for main drain checks.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Set of double doors on to pool deck with one door that opens freely and other with sensor so that door automatically opens from the exterior. One side of door permanently disabled. Permit restriction that door must remain permanently affixed. Other door, sensor disengaged. Door sensor disengaged during inspection. Mag-lock remains disengaged for over 30/45 seconds. Lower time so that it engages after 15 seconds.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Light fixture not affixed to wall. Gap. Corrected by operator during the inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational. Repaired during the inspection. No spare pump basket. Given one week to provide spare pump basket. Ensure pump basket is for approved pump Hayward Tristar XE SP3215X20XE. Photograph documentation ok for approval.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Weather stripping around bottom of doors for pump room and chemical storage room. Fresh air intake not installed in either room. Fresh air under door. Removed weather stripping during inspection. Weather stripping not permitted around base of door. If utilized, fresh air intake shall be installed.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Some stalls missing toilet paper in men's and women's restrooms. One toilet in women's restroom soiled. Keep all fixtures clean. Toilet paper replaced during the inspection.