Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRESERVE, THE
Address8725 KODY MARIE CT
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/14/2023
Final Score @ Grade
32
General CommentsPermit Denied. Facility failed pre-permit inspection. Contact main office at 980-314-1620 to pay re-inspection fee. Contact EHS at 704-621-2294 to schedule re-inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine testing 0ppm.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. .2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. .2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies. Observed no “NO DIVING” markers present. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. .2523(c) Depth markers shall include the word "feet" or symbol "ft". .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Observed depth markers not 4” in height in some markers and some did not include the word “feet” or “ft”.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed rubber caps missing from bottom feet of ladder.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed side door leading to pool deck near gym not self-latching and not child protected by audible alarm.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide required clearance of walking space around the pool at all times. Observed pool furniture 4 ft. 6 inches from edge of pool deck.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Observed Kings III phone number posted not audibly ringing back to the emergency phone and phone not answering once phone number is dialed. Goes to message stating Verizon wireless call could not be completed.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter not working when tested and not reading permit restriction requirements. Flow meter must remain operable with max flow of 106 gpa +/-5% due to filter size restriction.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at backwash line.