Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRESERVE AT PROVIDENCE
Address5931 PROVIDENCE RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/23/2026
Final Score @ Grade
14
General CommentsIssued permit. Gate horizontal must be corrected for 2027 permit per Tim Dutcher. No night swimming. Permit Restriction: Flow meter must remain operable. Flow must not exceed 98 gpm due to filter flow restriction. Flow greater than 119 gpm exceeds the drain covers. Suction Hazard. “A” Open for Business Inspection with Yoely Rosario and Mercedes Ortega Provided expired CPO, but has taken recent class. Provide updated CPO for future.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed 1 of 3 weirs missing. .2518(k) Replace missing weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder missing step and rubber end caps. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Front gate has horizontal at 40”. Horizontals on other parts of fence less than 45”. Gap in back of fence greater than 4”. Pool built 1979. .2528(a) Provide no openings in fence and/or gate that allows passage of a four inch diameter sphere. .2528(a) Horizontals shall not be located less than 45" in height. *Gate must be corrected for 2027 permit, remove or increase height on structural bar creating horizontal.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. No ventilation in pump/equipment room. No 3’ clearance around equipment. Original construction. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No paper towels in restrooms. .2526(m) Keep restrooms and fixtures clean and in good repair. Provide hand drying.