Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRESERVE AT PROVIDENCE
Address5931 PROVIDENCE RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/10/2025
Final Score @ Grade
24
General CommentsInspection completed with Robin Ventura and Mercedes Ortega present. All items listed on previous immediate suspension have been corrected and are in compliance (ring buoy in poor repair, emergency phone non operational, high pH). Observed one area on pool floor where paint/plaster is peeling. The health department recommends repairing/replacing this area in a timely manner. Failure to do so could result in your pool permit being suspended at a later date.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2537(7) Drain covers shall be in good condition and securely attached. Observed main drain cover completely detached from suction port at bottom of pool. CDI- maintenance reaffixed the drain cover. E. Freese verified the drain cover was secure.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2517(a)1 Diving equipment shall be installed per manufacturer's instructions. Observed 1 ladder with missing rubber end caps.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed throw rope connected to ring buoy at 50 feet. CDI- adjusted to 45 feet.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed door near restrooms not self-latching. CDI- repaired.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed phone number posted not accurate. CDI- correct phone number posted.