NameRESERVE AT PROVIDENCE
Address909 SUMMIT WALK DR
 
City/State/ZIP
CHARLOTTE NC 28270
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/5/2026
Final Score @ Grade
18
General CommentsNote: Skimmer equalizers are plastered over at wall and plugged in skimmer. No dummy covers. Update PDSC with this info by 8/12/2027 and submit to pdsc@mecknc.gov or permit action will be taken. No suction hazard. https://eh.mecknc.gov/pools Issued permit. No night swimming. Pool not heated. Changed to “A” Open for Business

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 1 out of 3 weirs stuck/not installed correctly at time of inspection. .2518(k) Replace missing weirs, install correctly.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One rubber cap missing on ladder. .2521 Install ladders per manufacturer instructions. Keep in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Front gate swings inward due to sidewalk with railing. .2528(b) Gates may only swing toward pool if built prior to May 1, 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool. Pool built 1986.
18 4 Premises: lifeguards present or warning signs posted No No No “Warning no lifeguard on duty” signage not meeting letter height requirement. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Operator posted correct signage.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals on floor in pump room. Chemicals in use in pump room. No ventilation in chemical storage. Original construction. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. .2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No hand drying in women’s restroom. .2526 Provide hand drying in restrooms.