Inspection Date 6/28/2023
Final Score @ Grade
28
General CommentsInspection completed with Mercedes Ortega present. Permit not issued due to items listed below. Correct these items before next inspection. A 100$ reinspection fee is also required to be paid prior to next inspection. Please call 980.314.1620 to make payment over-the-phone. Once items are corrected and fee is paid, contact Eli Freese at 704.621.2298 to schedule next inspection. 1. Maintain pH at 7.2 to 7.8. 2. Maintain emergency phone operational. 3. Maintain rope connected to ring buoy at 36 feet. 4. One equalizer line not plugged inside skimmer basket. 5. 3 out of 3 total missing weirs.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Obseved pH at 7.0. Permit suspended.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 3 out of 3 weirs not installed.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope at approximately 45 feet in length. Correct to 36 feet. Permit suspended.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed gate opening inwards towards the pool. No permit action taken as pool was constructed prior to 2010. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed one area underneath fencing near retention wall at 11 inches of clearance underneath fencing. No permit action as pool was constructed prior to 2010.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Observed emergency phone non-operational.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed water on floor due to leak at pump.