General CommentsInspection conducted with manager Amy Panunzio and maintenance staff Tee Anderson. CPO not present. Like for like filtration pump change. New WFK-12 pump. Prior to 2026 permit being issued, will need an electrical permit and passing inspection from Mecklenburg County Code Enforcement. Permit condition that filtration system requires 5% flow meter prior to 2026 permit being issued. Blue-White F-300 flow meter only accurate to +/- 10%, Blue-White F-1000 flow meter not installed per manufacturers instructions. Permit Restriction: Filtration pump flow meter must remain operable. Flow shall not exceed 138 gpm due to the flow restriction of the drain cover. Suction Hazard. Observed at 138 GPM today. Rubber vacuum adapter installed in skimmer closest to pump room. Cannot vacuum through the skimmers, must use vacuum line. Immediate suspension issued 15) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one of three weirs. .2518(k) Provide functional weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both ladders loose. .2521 Install ladders per manufacturer instructions. - Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope 36 feet long. Throw rope heavily frayed. .2530(a) Provide USCG approved ring buoy with attached 37 foot, 6 inch throw rope at least 1/4 inch in diameter. - Immediate suspension item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected. Sections of fence < 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Sections of coping cracked or with heavy chipping. .2537(2) Decks shall be kept in good repair. - Intent to suspend item.