| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
0.5ppm free chlorine. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 7.1. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Test kit expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Intent to suspend item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool walls and pool floor dirty, algae growing. Ensure pool is regularly brushed and vacuumed. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with leaves. Skimmer baskets matted with organic matter. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected, operator rinsed off skimmer baskets. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Both ladders loose. .2521 Install ladders per manufacturer instructions.
Handrail loose. .2521 Install handrails per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Sections of fence < 48” high due to pine needles. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Intent to suspend item.
Two fence panels temporarily in place. Missing brackets that permanently hold them in place. Noted on last inspection .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Intent to suspend item.
Post-2010 pool with gaps > 2” under fence in places. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Intent to suspend item. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chlorinator not able to keep pool chlorinated. This has been a recurring issue. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Digital flow meter not operating. Permit condition is that flow meter must remain operable due to flow restriction for main drains. .2518(g) Keep flow meter operational. - Immediate suspension item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some labeling on piping faded. .2518(d) Piping and valves shall be labeled with color codes or labels. |