NameRESIDENCE INN/COURTYARD INN NORTHLAKE
Address9110 HARRIS CORNERS PY
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/3/2024
Final Score @ Grade
42
General CommentsInspection conducted with Tony Lockhart. Emergency phone number calls back to front desk. Ensure front desk is staffed whenever the pool is open. Ring buoy is not US Coast Guard approved. Orange hard plastic ring buoy stamped solas 96 msc.81(70). Will follow up to see if approved. If not approved, will need to replace with US. Coast Guard approved ring buoy. Immediate suspension issued 2) 3) 24) Contact Will Harrison (704-507-6824) to schedule re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No 0.5ppm free chlorine. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
3 6 Water quality: pool water pH No No No PH 7.1. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Test kit expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool walls and pool floor dirty, algae growing. Ensure pool is regularly brushed and vacuumed. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets with leaves. Skimmer baskets matted with organic matter. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected, operator rinsed off skimmer baskets.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both ladders loose. .2521 Install ladders per manufacturer instructions. Handrail loose. .2521 Install handrails per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Sections of fence < 48” high due to pine needles. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Intent to suspend item. Two fence panels temporarily in place. Missing brackets that permanently hold them in place. Noted on last inspection .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Intent to suspend item. Post-2010 pool with gaps > 2” under fence in places. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Intent to suspend item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Chlorinator not able to keep pool chlorinated. This has been a recurring issue. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Digital flow meter not operating. Permit condition is that flow meter must remain operable due to flow restriction for main drains. .2518(g) Keep flow meter operational. - Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some labeling on piping faded. .2518(d) Piping and valves shall be labeled with color codes or labels.