Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRESIDENCE INN/COURTYARD INN NORTHLAKE
Address9110 HARRIS CORNERS PY
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/18/2024
Final Score @ Grade
50
General CommentsInspection conducted with CPO Richard Sheppard. Richard is the new CPO for this pool. Updated our files. *Note* Blue-White flow meter reads 138 GPM, is not capable of reading 1.5x the pump design flow of 135 GPM. Required electronic flow meter was not working on today’s inspection. Immediate suspension issued 2) 6) 15) 24) Contact Will Harrison (704-507-6824) to schedule re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Observed remains of chlorine puck in skimmer. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. - Corrected. Removed by operator. No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Observed VGBA-2017 Aquastar A10RCFR101 covers installed for pool feature drains. Does not match what we have on file. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Immediate suspension item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Heavy buildup of organic matter on pool walls, some debris on pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets with leaves. Heavy buildup of organic matter inside the skimmers. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both ladders loose. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Outer rope on ring buoy and throw rope heavily frayed. .2530(a) Provide USCG approved ring buoy with attached 37 foot, 6 inch throw rope at least 1/4 inch in diameter. - Immediate suspension item. Screws loose on body hook. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Immediate suspension item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Sections of fence < 48” high due to pine needles. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Intent to suspend item. Two fence panels knocked out. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Partially corrected, operator able to reinstall, but missing brackets to hold them securely in place. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Chlorinator not able to keep pool chlorinated. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Digital flow meter not operating. Permit condition is that flow meter must remain operable due to flow restriction for main drains. .2518(g) Keep flow meter operational. - Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.