Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameNORTHLAKE APARTMENTS
Address8215 CRESCENT RIDGE DR
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/12/2024
Final Score @ Grade
34
General CommentsInspection conducted with CPO Romulus Crowell. Observed new 2.5” flow meter installed on 2.5” return line. Clubhouse and restrooms recently remodeled. New restroom mirrors and showers installed. Did not go through in-field plan review. Prior to permit being issued, will need to provide documentation that mirrors are shatterproof or have safety backing, documentation for floor tiles that flooring is slip resistant, and show that flooring slopes to floor drains. Pre-permit inspection did not pass 3) 16) 17) 22) In-Field plan review items for restrooms Prior to scheduling re-inspection, will need to pay $100 re-inspection fee by calling our office (980) 314-1620 and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing non-slip tread. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy damaged. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope at least 1/4” in diameter. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence as short as 43” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Magnetic paddles < 45” high. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item. Door at restrooms not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Pre-permit item. Gates not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing - Pre-permit item. Gap > 2” under gate at pump room. .2528(a) Maintain 2" or less under fence and/or gate. - Pre-permit item. Less than 45” between horizontals on gate at pump room. .2528(b) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate. - Pre-permit item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Piece of coping by pool steps loose. .2537(3) There shall be no loose coping. - Pre-permit item.
22 6 Premises: emergency telephone provided No No No Phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some items stored beside pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Fan not working in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap on backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No toilet paper dispensers in the restrooms. .2526(l) Provide toilet paper on a dispenser in restrooms. No soap in the restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink.