Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameNORTHLAKE APARTMENTS
Address8215 CRESCENT RIDGE DR
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/24/2023
Final Score @ Grade
20
General CommentsInspection conducted with CPO Jason Page. Verified pre-permit items from previous inspection were corrected. Coping chipped and flaking in places. Recommend repairing/replacing. No label on pool pump. Verified PAC-Fab Challenger pump with 3 HP motor. Permit issued with the following conditions No Night Swimming Pool built with 3 skimmers and no vacuum line. Must use a portable vacuum to clean the pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent total alkalinity or cyanuric acid readings. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Corrected. CPO tested cyanuric acid and total alkalinity today.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Magnetic paddles < 45” high. .2528(b) Horizontals shall not be located less than 45" in height. - Corrected. Added angled metal over foothold. Pre-2010 fence as short as 43” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap on backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Toilet paper dispenser missing in men’s restroom. .2526(l) Provide toilet paper on a dispenser in restrooms.