Inspection Date 5/1/2023
Final Score @ Grade
36
General CommentsPre-permit inspection conducted with CPO Jason Page. Coping chipped and flaking in places. Recommend repairing/replacing. No label on pool pump. Verified PAC-Fab Challenger pump with 3 HP motor. Facility built without a vacuum line and 3 skimmers. Condition of the permit is that pool use a portable vacuum to clean the pool. - Facility has a portable vacuum. Doors to maintenance room not self-closing and self-latching. Will need to be kept closed and locked when not in use so that the public is not able to use that to access the pool. Conduit damaged and not attached to the pump motor, exposing wiring. - G.S. 130A-2(3) Ensure no electrical hazards exist in the pump room. - Pre-permit item. Motor not bonded to the pool. - G.S. 130A-2(3) Bonding wire shall be attached to the pump motor. - Pre-permit item. Pre-permit inspection did not pass. All items noted “pre-permit item” need to be addressed before a permit can be issued. Will need to pay a $100 re-inspection fee by calling our office (980-314-1620) and paying with a credit card prior to scheduling a re-inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Missing two eyeball fittings. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Magnetic paddles < 45” high. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item. Door to managers office not self-closing. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Pre-permit item. Pre-2010 fence as short as 43” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Fill spout located more than 6 inches from ladder. .2512(c) Over the rim fill spouts shall be located under the diving board or within six inches of a ladder or handrail and be at least two pipe diameters above the deck or pool overflow level. - Pre-permit item.
18 4 Premises: lifeguards present or warning signs posted No No No Safety signage peeling. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Pre-permit item. Safety signage peeling. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Pre-permit item. Safety signage peeling. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Pre-permit item.
19 4 Premises: signs prohibit glass containers or pets in pool area No No No Safety signage peeling. .2530(d) Provide a sign prohibiting pets and glass containers in the pool area.
22 6 Premises: emergency telephone provided No No No Phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap on backwash line. .2513(b) Filter backwash shall be discharged through an air gap.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Safety signage peeling. .2526(a) Post a shower sign visible upon entrance to the pool.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Toilet paper dispenser missing in men’s restroom. .2526(l) Provide toilet paper on a dispenser in restrooms.