|
20
|
1.50
|
Proper cooling time & temperatures |
Yes |
No
|
No |
3-501.14 Cooling (P)
Previously cooked and shredded fried chicken (prepared the previous day) had a temperature of 51F after being cooled inside of the produce walk-in cooler. Cooked time/temperature control for safety food shall cooled within 2 hours from 135F to 70F and from 70F to 41F within an additional 4 hours (6 hours total). The manager voluntarily discarded the shredded fried chicken during the inspection. CDI |
|
33
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Cooling Methods (Pf)
Effective cooling methods were not used to cool shredded, fried chicken within the allotted 6-hour time frame. For cooked foods, cooling shall be accomplished within 6 hours to 41F by using effective cooling methods such as placing cooked foods inside of the walk-in freezer (for rapid cooling), dividing cooked foods into smaller/thinner portions, or placing the food into pre-chilled shallow pans. The REHS recommended to the manager that the restaurant place its cooked foods onto a speed rack and place the speed rack into the walk-in freezer for rapid cooling. CDI |
|
41
|
0
|
Wiping cloths: properly used & stored |
Yes |
Yes
|
No |
3-304.14 Wiping Cloths, Use Limitations (C)
Wet wiping cloths (not in active use) were being stored inside of QUAT sanitizer solution with a QUAT concentration of 0 ppm. Cloths in-use for wiping counters and other equipment surfaces shall be held in a chemical sanitizer solution within the required concentration range. For QUAT-based sanitizers, the required concentration range is 200 ppm to 400 ppm. The manager discarded the QUAT sanitizer solution during the inspection. CDI, R |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Good Repair and Proper Adjustment - Equipment (C)
One of the lids to the buffet’s ice cream machine has a hole in it and needs replacing. Equipment shall be maintained in a state of good repair. |
|
52
|
1
|
Sewage & wastewater properly disposed |
No |
No
|
No |
5-403.12 Other Liquid Wastes and Rainwater (C)
A steady flow of condensation (from the restaurant’s A/C system) was seen dripping outside of the restaurant onto the ground. A large puddle of liquid was also seen on the ground in between the restaurant and the outside fencing. Condensate drainage and other nonsewage liquids and rainwater shall be drained from point of discharge to disposal according to the law. |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-303.11 Intensity - Lighting (C)
Brighter lighting is needed beneath the kitchen hood system. The lighting at the kitchen grill was reading 25 ft/c (foot-candles) during today’s inspection. The lighting intensity shall be a minimum of 50 ft/c (foot-candle) above surfaces where employees work with food or with equipment/utensils used to prepare food. |