16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
Yes |
No
|
No |
4-601.11(A) Equipment food contact surfaces and utensils shall be clean to sight and touch. -Pf. Observed several storage containers in the clean dish storage area soiled with old chicken debris and grease. CDI- All items taken to be washed.
4-501.114 Maintain sanitizer at correct concentrations when being used to sanitize. -P Observed dish machine pulling sanitizer at a low concentration 50ppm>. CDI- Line is bent and is creating air gaps in line. Line straightened to properly pull sanitizer, CDI- Dishes re-washed.
For more information, please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg , How to Test Sanitizer https://youtu.be/y0SjmnabFaY , and Cleaning and Sanitizing Food Contact Surfaces https://youtu.be/av1Rbh-lh08
For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg and How to Test Sanitizer https://youtu.be/y0SjmnabFaY |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed sanitizer line bent for dish machine. Get line fixed so that sanitizer can be pulled at the proper concentration. |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
Yes |
4-302.14 Provide a test kit that accurately measures sanitizer concentrations. -Pf Observed no test strips for dish machine and sink sanitizer. Get test strips. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed floors in need of cleaning under and around equipment. |