10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
Safety rope not installed at breakpoint due to lane lines installed. Advised safety rope should be installed at breakpoint. Rope available for use when lane lines removed. Operator aware of required usage. Corrected. .2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Right door on double door closest to parking area not self-latching.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
Operator tightened to self-close, self-latch and corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Cones within 8’ clearance of pool.
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). Operator moved and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
A few small containers of chemicals in equipment room by control area.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |