10
|
0
|
Handwashing sinks supplied & accessible |
Yes |
No
|
No |
6-301.12 Provide paper towels or approved alternative for hand drying at each handsink. -Pf Observed no paper towels at second hand sink near warewashing. CDI- PIC restocks paper towels. (-0) |
|
22
|
1.50
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P Observed multiple TCS foods inside WIC between 42F-46F. PIC states a large delivery had WIC door open just before inspection began. EHS observes ambient temperature return to <41F, as well as all TCS foods, within 25 minutes. EHS advises PIC to monitor the WIC during deliveries and ensure food is able to quickly recover back to 41F. (-1.5)
For more information, please visit: www.mecknc.gov/foodsafety or view our training videos at the following weblinks: What are TCS Foods https://www.youtube.com/watch?v=q0iLZb7v0UM and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . |
|
43
|
0.50
|
In-use utensils: properly stored |
Yes |
No
|
No |
3-304.12 (F) Containers of water used for storing in-use utensils must be maintained at a temperature of at least 135 F and cleaned at least every 24 hours or when container has accumulated soil or residue. Observed multiple in-use utensils in 119F water at stove. CDI- PIC brings water up to 165F and states they will maintain 135F or higher going forward. (-0.5) |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Observed slow drainage at first hand sink upon entry to back kitchen area. Repair plumbing at earliest opportunity. (-0) |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed cracked tiles on floor near ware-washing, allowing water to pool in between cracks. Repair at earliest opportunity. (-0)
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed spills, grease, and food residue on various walls throughout facility. Increased cleaning frequency recommended. REPEAT. (-1) |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
Yes |
No
|
No |
6-305.11/6-501.110 Designate and use an area for the orderly storage of employees' clothing and possessions. Observed employee phones on prep table near food. CDI- PIC moves phones to segregated area. (-0) |