15
|
0
|
Food separated & protected |
Yes |
No
|
No |
3-302.11(A)(8) Separate unwashed produce from ready-to-eat foods. For more information on food storage order please visit: http://meck.co/FoodSafety Observed unwashed produce stored directly above RTE salad dressings and other RTE foods in RI cooler. CDI - PIC rearranged storage order. -0- |
|
23
|
1.50
|
Proper date marking & disposition |
Yes |
No
|
No |
3-501.18 Discard the food requiring date labels once time/temperature window has expired, if it is not been labeled, or if the label is incorrect. -P For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Date Marking Food Safely https://youtu.be/BOPsSNUajYs . Observed expired house made Caesar’s salad dressing date marked 09/21/2022 and cheese date marked 09/17/2022. CDI - PIC voluntarily discarded. -1.5- |
|
25
|
0.50
|
Consumer advisory provided for raw/ undercooked foods |
No |
No
|
Yes |
3-603.11 (C )(2) A Consumer Advisory Reminder shall include asterisking the food item to a footnote that states: * Consuming raw or undercooked meats, poultry, seafood, shellfish, or eggs may increase your risk of foodborne illness.- Pf Observed footnote present on printed menu without asterisk tying menu items to footnote. VR no later than 10/10/2022. -.5- |
|
39
|
1
|
Contamination prevented during food preparation, storage & display |
No |
No
|
No |
3-305.11 Store food in a clean, dry location, not exposed to contamination. Keep at least 6 inches above the floor. Observed boxes of fries stored directly on floor in walk in freezer and dehydrator with citrus slices inside stored directly on floor in upstairs bar. Keep off floor. -1- |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Observed handsink removed and placed outside that was present during permitting. Re-install handsink and maintain per plumbing LAW. -0- |
|
53
|
0
|
Toilet facilities: properly constructed, supplied & cleaned |
No |
No
|
No |