Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameKALEIDO NODA APARTMENTS
Address2830 CULLMAN AVE
 
City/State/ZIP
CHARLOTTE NC 28206
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/13/2026
Final Score @ Grade
6
General CommentsIntent to Suspend (ITS) Issued for gates, doors and fencing. Contact Marie Daley at 704-507-6806 when corrected to lift ITS. Inspection with Alex DeCristo and Hector Santiago Pool not heated. No night swimming. Pool rules signage indicates 10 pm and 9 pm closure. Advised posting signage to state “No Night Swimming” or pool closure hours noted to reflect no swimming before dawn or after dusk. Operator advised pool is closed. Closure sign only posted at one side gate. Post signage at all bather entrances including main doors onto pool deck. Discussed resident patio furniture being moved to eliminate horizontals less than 45” in height. Windows should not open greater than 4” onto pool deck. Discussed seasonal permits valid April 1-October 31 if desired and pool is not operating outside of these dates, amenities can remain open with pool closed year round.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Side gate not latching at time of inspection. Double glass door sensor to pool deck not turning off, allowing door to be opened without latching or alarm. Yoga studio door not staying latched or alarmed, sensor allows door to be opened. There is garage door that opens onto pool deck in yoga room. Fence with gap greater than 2” under it with rocks. Some mesh missing from bottom right of left side gate with opening greater than 1/2” within 18” of latching mechanism. .2528(a) Maintain 2" or less under fence and/or gate (post-May 1, 2010). .2537(b) All gates and doors shall be self-closing, self-latching. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. .2528(a) Ground level doors shall be self-closing, self-latching or self-closing and child protected by audible alarm. *Permit item Operator filled in gaps with rocks under fence.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak at return, floor wet in pump room. Some tubs of chemicals stored in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.