48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
Yes |
4-302.13 (B) Provide an approved Max/Min thermometer for testing sanitizing temperatures in hot water warewashing machines. The thermometer must be readily accessible. -Pf: must have a max/min thermometer, dish plate, or therma-labels in addition to thermometer on dish machines in both kitchens. |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
No
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed black residue on 3-door reach in cooler in AL kitchen. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed dust build up on HVAC vents in dry storage in both kitchens. |