Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLA FITNESS - WOMENS SPA
Address3024 PROSPERITY CHURCH RD
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 1/16/2025
Final Score @ Grade
22
General CommentsNote: Grout redone within 4 ft of spa edge. Note removed from file. Intent to Suspend issued for: .2535 - record keeping. Provide log book for December 2024. .2535 - automated feeder shall detect flow from pump. Demonstrate feeder set up to detect flow. Feeder not calibrated correctly. Calibrate. Matt Fenz present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Temperature not recorded daily for January 2025 log. Records not available for December 2024. Provide logs for December. Intent to Suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some discoloration on spa floor. Continue to monitor. May require repair in future if darkens. Pool plaster shall reflect >50% light.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Main door from locker rooms to pool propped open. Repeat item. Recommend replacing handle. Door gets propped open since handle does not work at all times. If continued issue, will require replacement of handle. Door shall remain closed. Corrected during the inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Water holding deck behind handicap lift. If algae or area becomes slick, will require repair. Deck shall be free of standing water.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Pool operator not onsite during inspection and could not verify that automated feeder detects flow of pump. Intent to Suspend issued. Feeder shall detect flow and turn off with loss of flow. Feeder reading pH at 7.7 with pH in spa at 7.2. Calibrate feeder. Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Bag of bicarb stored on chemical storage room floor. Placed in bag; however, bag is ripped. Maintain dry chemical storage off floor if bags are not waterproof. Chemical storage room door rusted on inside and sticking open at hinge due to rust. Ensure adequate ventilation.