Water quality: pool water pH |
No |
No
|
No |
Spa pH greater than 8.6. Maintain pool pH at 7.2 to 7.8. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No logs for August. Maintain daily record keeping for chlorine, pH and main drain checks. Maintain weekly record keeping for total alkalinity and cyanuric acid. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some discoloration on spa floor. Continue to monitor. May require repair in future if darkens. Pool plaster shall reflect >50% light. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door from pool to locker rooms propped open. Door is sticking. Will require repair once permit is re-instated. Re-occurring issue for several inspections. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some coping edge missing grout. Repair as needed. Opening not greater than 1/2". |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Automated feeder reading 8.2 but not providing acid to pool to lower acid. Requires repair prior to reopening the swimming pool.
Feeder could not be tested to detect flow. Feeder shall detect flow with no flow to pump and turn off with no flow.
Tubing for chemical feeder hangs in front of chemical storage door so not accessible. Move tubing/secure to wall to ensure chemical storage room is accessible. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Small leak around filter lid. Repair leak. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemical storage room door rusted on inside and sticking open at hinge due to rust. Ensure adequate ventilation. |