Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLA FITNESS - MENS SPA
Address3024 PROSPERITY CHURCH RD
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 11/4/2025
Final Score @ Grade
22
General CommentsInspection conducted with inspector Niejel Wilkins and CPO Nalkus Mincer. Standing water on pool deck. Maintain deck in good condition and sloped to deck drains. Men’s spa floor chipping. Maintain in good condition. Intent to suspend issued 5) 12) 14)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 8.1. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.3.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Facility has 3 bodies of water, log sheet only has a place for two. No place on log sheet for temperature checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for total alkalinity and cyanuric acid if used. - Left copy of state log sheet. Intent to suspend item.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Some eyeball fittings for jets missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item.
14 4 Pool maintenance: spa timer working properly No No No Spa timer > 15 minutes. .2537(b) Spa times shall not exceed 15 minutes without manual resetting. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Bags and boxes of chemicals stored by pumps. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Bags of sodium bicarbonate stored on pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms 120F. .2526(i) Water in restrooms shall not exceed 110 F.