Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLA FITNESS
Address3024 PROSPERITY CHURCH RD
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/14/2024
Final Score @ Grade
20
General CommentsInspection conducted. Went over inspection with manager Matthew Fenz. *Note* Some barrels of liquid chemicals are not labeled. Label all chemical containers clearly per manufacturer’s instructions. CPO not present. Not able to test automatic controllers. Ensure automatic controllers shut off when pump when pump is off. *NOTE* - Prior to 12-31-2024, all depth markers need to be permanently grouted in place and meet all requirements in .2523. Intent to suspend issued 5) 8) 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records since Friday 10/11. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for total alkalinity and cyanruic acid if used. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water level a few inches below the overflow trough on the gutter. Top step above the water. .2518(k) Water level shall be maintained above the level of the overflow trough on gutter. - Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No One ring buoys with heavily knotted throw rope. .2530(a) Provide USCG approved ring buoy with attached 33 foot throw rope at least 1/4 inch in diameter. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door to fitness area does not latch. .2528(a) Ground level doors shall be self-closing, self-latching. - Intent to suspend item. Door to men’s locker room does not latch. Mortise taped over. .2528(a) Ground level doors shall be self-closing, self-latching. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemical drums stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.