Premises Information

Return to Inspections
NameACCENT SOUTHRAIL APARTMENTS
Address6026 STATION CROSSING AVE
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/8/2026
Final Score @ Grade
14
General CommentsInspection conducted with CPO, James Jackson. Permit restriction: Pump must remain at 3450 RPM due to design specifications of system and turnover Note: Pool not approved for salt as primary chlorination. -Auto chlorination interlock tested and operational. -Night swimming NOT allowed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Install skimmer per manufacturer specifications and eliminate equalizer line plugs or plug per State requirements. Observed 6 equalizers in skimmer baskets without plugs. According to PDSC form, establishment should have equalizers lines disabled and plugged. EHS will follow up with CPO and ensure correction in coming week. CPO encouraged to reach out with any questions, or once completed. CPO advised to ensure water is cleared from lines before plugging.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed deteriorated rope snap from ring buoy with mild tension applied. Corrected- CPO replaces with new rope, 50 feet in length, during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed one push-bar latch mechanism gate onto pool deck self latch, but not self close. Corrected- CPO tightens hinges and gate self closes, self locks.