8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Install skimmer per manufacturer specifications and eliminate equalizer line plugs or plug per State requirements.
Observed 6 equalizers in skimmer baskets without plugs. According to PDSC form, establishment should have equalizers lines disabled and plugged.
EHS will follow up with CPO and ensure correction in coming week. CPO encouraged to reach out with any questions, or once completed.
CPO advised to ensure water is cleared from lines before plugging. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.
Observed deteriorated rope snap from ring buoy with mild tension applied.
Corrected- CPO replaces with new rope, 50 feet in length, during inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present.
Observed one push-bar latch mechanism gate onto pool deck self latch, but not self close.
Corrected- CPO tightens hinges and gate self closes, self locks. |