Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameINFINITY 260
Address11020 DAVID TAYLOR DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/3/2023
Final Score @ Grade
22
General CommentsInspection conducted with maintenance staff and property manager. Keyfob not working for door to apartment building. Will check to ensure door is self-closing and self-latching on next visit. Doors around grill area still blocked off. Did not inspect to ensure doors are self-closing and self-latching. Have had issues on previous visits with low chlorine levels in the pool. Recommend having properly installed and functional flow meter on line to erosion flow meter to monitor if it is working properly. Immediate suspension issued 2) Contact Will Harrison (704-507-6824) for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Observed Cl at 0.4 ppm. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item. Chlorine tabs in all of the skimmers. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. - Immediate suspension item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Most skimmers full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Both gates not self-closing and self-latching. One gate stuck closed. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Salt cells not working, low salt levels. Does not appear erosion chlorinator is working properly. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak at pump. .2533(d) Pump room floor shall be kept dry and free of standing water.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in the restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.