Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameINFINITY 260
Address11020 DAVID TAYLOR DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/3/2023
Final Score @ Grade
26
General CommentsInspection with CPO Carlos Hernandez and Hardcor Coleman. Did not fully inspect grill area or doors leading to the pool deck near the grill area. Currently closed off. Ensure doors are self-closing and self-latching. Facility built without main drains to completely drain the pool. Will need to provide a sump pump to be able to drain the pool when needed. Pool did not pass pre-permit inspection 2) 5) 15) 16) Sump pump. There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No 0.8 ppm free chlorine. .2535(4) Maintain chlorine at least 1.0 ppm. - Pre-permit item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Ensure chemicals are checked daily. Chlorine consistently 11, I tested today at 0.8ppm. No main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity. - Pre-permit item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook not attached to the pole. .2530(a) Provide at least 12 foot long non-collapsible pole with body hook securely attached with both screws. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence as short as 43” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Pre-permit item. Gaps > 2” under the fence in places due to mulch erosion. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). - Pre-permit item. Gate latch < 54” high. .2528(a) Gate latches shall be 54" in height. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not working. .2518(g) Keep flow meter operational. - Pre-permit item. No spare filter cartridges. .2519(j) Provide two sets of filter cartridges for cartridge filter. - Pre-permit item.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in the restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.