26
General CommentsInspection conducted with Philip Getson. Ensure pool equipment is working properly. Air bubble in flow meter, high filter pressure, low flow in skimmers. Main drains expire 3-1-2027. Prior to expiration, replace with new APSP-7/APSP-16 approved drain covers and submit updated PDSC forms to our office for approval. Observed decking and fencing expanded for new grill and gazebo that were added to the pool deck. New fencing does not meet Health Department requirements. Does not appear that permits and inspections were obtained from Mecklenburg County Code Enforcement. Will need to submit plans and get passing inspections from Mecklenburg County Code Enforcement. Gate to secondary entrance by grill area screwed shut. This is an emergency egress exit. Ensure all Fire Marshall emergency egress requirements are met. Pre-permit inspection did not pass. All items marked as pre-permit items must be corrected prior to scheduling a re-inspection with Will Harrison (704) 507-6824. Prior to scheduling a re-inspection, will need to pay a $100 re-inspection fee by calling our office (980) 314-1620 and paying with a credit card. 7) 8) 11) 15) 16) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Leaves on pool floor and floating on water’s surface. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Pre-permit item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing non-slip tread. .2521(b) Ladders shall have slip-resistant tread. Ladder loose. .2521(b) Ladders shall be installed rigidly. Handrails loose. One handrail not installed in the anchor. Handrail removed. .2521 Install handrails per manufacturer instructions. - Pre-permit item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No New US Coast Guard approved ring buoy with 50 foot throw rope. .2530(a) Provide USCG approved ring buoy with attached 30 foot throw rope. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Some pickets bent, openings > 4 inches through the fence. New section of fencing with gaps > 4” through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Pre-permit item. New section of fencing added. New section with gaps > 2” under the fence. .2528(a) Maintain 2" or less under fence and/or gate (post-May 1, 2010). - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not working properly, large air bubble in the flow meter. .2518(g) A flow meter, reading in gallons per minute, shall be installed per manufacturer instructions. - Pre-permit item.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in women’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.