2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. Observed pool to be at 0.0 ppm chlorine. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be 6.8. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no records kept for pool since 10/10/2026. Observed there to be no alkalinity checks on the record sheet. All of the proper checks must be done every day the pool is open for swimming. This includes weekends and holidays. Failure to have alkalinity checks was mentioned on the previous inspection 5/28/2026. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers to be full of debris to the level where it was creating suction against the removal of the baskets. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed some eyeball fittings missing. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Also observed a gap under the fence greater than 4 inches.
Observed gates to have new latches installed that are at 41 inches and 39 inches high from the ground. They protrude more than 2 inches out. As they are under 45 inches in height, they need to be covered be a 45 degree angled surface to prevent them from being a foothold. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
One filter has an air gap, other filter not backwashed through an air gap. .2513(b) Filter backwash shall be discharged through an air gap. |