General CommentsInspection conducted with CPO Nasir Clemmons and inspector Hope McIntosh. Verified items from previous inspection corrected. Conducted inspection. Verified flow meter reading 118 GPM after a backwash. Permit issued with the following conditions No Night Swimming Permit condition that flow meter must remain operation and is required to read between 106 and 146 GPM. Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH < 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.3.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No place on log sheet for total alkalinity checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Far skimmer basket broken. .2518(k) Replace missing or damaged skimmer basket. - Corrected. CPO ordered new skimmer basket.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Handrail missing escutcheon plates. .2521 Install handrail per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not functioning. .2518(g) Keep flow meter operational. - Corrected.
27 2 Equipment room: filter backwash discharged through an air gap No No No One filter has an air gap, other filter not backwashed through an air gap. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Out of toilet paper in men’s restroom. .2526(l) Provide toilet paper and dispensers in restrooms. No soap in men’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.