Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameONE NORMAN SQUARE APARTMENTS
Address19532 ONE NORMAN BOULEVARD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/3/2025
Final Score @ Grade
18
General CommentsInspection conducted with CPO Yovanney Geronimo. Verified items from 6/23 and 7/2 inspection and conducted pre-permit inspection. - When pool steps were replastered, last step was made into a slope. Slope is 3:8 rise to run on one end, 4:14 on the other end before slope gets less steep and merges with pool floor. When pool is replastered next, will need to make step area complaint with section .2516 of the pool rules. - Pump set at 2600 RPM. No pump curve for 2600 RPM. - Permit condition that flow is required at 106 to 146 GPM to meet turnover and flow restriction of the filters. Will need to keep operable pressure gauges n place to measure flow and set pump at an RPM for which there is a pump curve. - Adjusted to 3110 RPM. -3110 RPM (2.31x20psi) + (1.13x6.75 in Hg) = 54 TDH = 131 GPM on pump curve. Issues corrected Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records. Permit sticker issued with the following conditions: - No night swimming. - Flow meter must remain operable. Flow required at 106 to 146 GPM to meet turnover and flow restriction of the filters. - Pressure gauges must remain in place and operable due to flow restriction of the filter unless properly installed flow meter is in place.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one weir. .2518(k) Provide functional weirs. - CPO has weirs on order.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6” into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Handrail missing escutcheon plates. .2521 Install handrail per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No FlowVis flow meter only reads up to 110 GPM. .2518(g) Install flow meter on return line per manufacturer instructions that is capable of reading between minimum turnover and the maximum velocity of the piping. - Will give facility 30 days to make corrections.
27 2 Equipment room: filter backwash discharged through an air gap No No No One filter has an air gap, other filter not backwashed through an air gap. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Restrooms renovated. Provided documentation that mirrors are shatterproof. .2526(k) Provide shatterproof mirrors. - Will give facility 30 days to make correction.